CLI Guide

MaximumWarningThreshold = 45 C
MinimumFailureThreshold = 3 C
MaximumFailureThreshold = 55 C
TempSensor.Embedded.3:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = Temp Sensor 3
ReadingDegreeCelcius = 25 C
MinimumWarningThreshold = 10 C
MaximumWarningThreshold = 46 C
MinimumFailureThreshold = 3 C
MaximumFailureThreshold = 55 C
TempSensor.Embedded.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = Temp Sensor 0
ReadingDegreeCelcius = 32 C
MinimumWarningThreshold = -2 C
MaximumWarningThreshold = 65 C
MinimumFailureThreshold = -2 C
MaximumFailureThreshold = 65 C
TempSensor.Embedded.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = Temp Sensor 1
ReadingDegreeCelcius = 31 C
MinimumWarningThreshold = -2 C
MaximumWarningThreshold = 65 C
MinimumFailureThreshold = -2 C
MaximumFailureThreshold = 65 C
TempSensor.Embedded.2:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = Temp Sensor 2
ReadingDegreeCelcius = 27 C
MinimumWarningThreshold = 12 C
MaximumWarningThreshold = 50 C
MinimumFailureThreshold = 3 C
MaximumFailureThreshold = 55 C
TempSensor.Embedded.3:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = Temp Sensor 3
ReadingDegreeCelcius = 26 C
MinimumWarningThreshold = 13 C
MaximumWarningThreshold = 46 C
MinimumFailureThreshold = 3 C
MaximumFailureThreshold = 55 C
hotspare
Table 96. Details of hotspare
Description
Assign or unassign global and dedicated hotspares.
Synopsis
racadm raid hotspare:<PD FQDD> -assign {yes | no} {type {ghs | dhs}} {-
vdkey:<VD FQDD>} {-current | -pending}
Input
–current <optional>: Performs the conguration right now.
NOTE: If this requires the system to reboot it will reboot then.
–pending: Save the conguration change for a later application. You can use a combination of the –pending and
–current ags on multiple commands to reduce the possible number of system reboots.
84 RACADM Subcommand Details