CLI Guide

-rp {nra|ra|ara}: Set the read policy to No Read Ahead, Read Ahead, or Adaptive Read Ahead.
-ss: Specify the stripe size to use.
-sc: Number of spans in the virtual disk. This value must be entered while creating spanned RAID levels such as
10, 50, and 60.
-pdkey: <PD FQDD list>: The PDs to use in the VD.
-dcp: Set the Disk Cache Policy in the VD.
enabled: Enabled – Allow the disk to use its cache.
disabled: Disabled – Disallow the disk from using its cache.
default: Default – Use the default cache policy. SAS Drives - Use Disabled by Default. SATA Drives - Use
Enabled by Default.
–name: <VD name>: The name to give the VD.
–size: <VD size>: The size of the VD.
b: Specify the size in bytes.
k: Specify the size in kilobytes
m: Specify the size in megabytes.
g: Specify the size in gigabytes.
t: Specify the size in terabytes.
-cc: Create a CacheCade or Enhanced Cache VD.
-vdinit: Create a virtual disk with or without initialization. The available values are:
yes
no
If -vdinit is not specied, the default value is “yes.
-secure: Create a virtual disk using Self-Encrypting Drives (SEDs). The available values are:
yes
no
If -secure is not specied, the default value is “no.
Example
racadm raid createvd:RAID.ChassisIntegrated.1-1 -rl r0 -pdkey:Disk.Bay.
0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
NOTE: Make sure to provide the current active controller FQDD in the createvd command.
deletevd
Table 86. Details of deletevd
Description
Deletes the specied virtual drive.
Synopsis
racadm raid deletevd:<VD FQDD> {-current|-pending}
Input
–current <optional>: Performs the conguration right now.
NOTE: If this requires the system to reboot, it will reboot.
–pending: Save the conguration change for a later application. You can use a combination of the –pending and
–current ags on multiple commands to reduce the possible number of system reboots.
Example
racadm raid deletevd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
RACADM Subcommand Details 75