CLI Guide

blink
Table 84. Details of blink
Description
Starts blinking or identies operation on the specied device.
NOTE: The physical disks associated with the adapter blink or unblink.
Synopsis
racadm raid blink:<PD FQDD>
racadm raid blink:<VD FQDD>
racadm raid blink {-pdkey:<comma separated PD FQDDs|-vdkey:<comma separated VD
FQDDs}
racadm raid blink:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Input
–pdkey: A comma-separated list of physical disk drive FQDDs to use in the operation.
–vdkey: A comma-separated list of virtual drive FQDDs to use in the operation.
Example
racadm raid blink:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
racadm raid blink:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid blink -pdkey:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1,Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
racadm raid blink -vdkey:Disk.Virtual.0:RAID.ChassisIntegrated.1-1,Disk.Virtual.
0:RAID.ChassisIntegrated.1-1
racadm raid blink:Enclosure.External.0-0:RAID.ChassisSlot.5-1
createvd
Table 85. Details of createvd
Description
Creates a virtual disk based on the specication that you enter with this command.
NOTE: You can create multiple virtual disks using the script at an instance. But, ensure that there is an
interval of about 30 seconds to facilitate completion of the rst slice virtual disk creation before running
the second slice virtual disk command.
Synopsis
racadm raid createvd:<Controller FQDD> -rl {r0|r1|r5|r6|r10|r50|r60} [-wp {wt|
wb|fwb}] [-rp {nra|ra|ara}]
[-ss {1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}] -pdkey:<comma
separated PD FQDD>
[-dcp {enabled|disabled|default}] [-name <VD name>] [-size <VD size>{b|k|m|g|
t}] [-cc]
[-sc {span count}] {-current|-pending} [-vdinit {yes|no}] [-secure {yes|no}]
Input
-rl: Set the RAID Level.
r0: RAID 0 – Striping.
r1: RAID 1 – Mirroring.
r5: RAID 5 – Striping with Parity.
r6: RAID 6 – Striping with Extra Parity.
r10: RAID 10 – Spanned Striping with Mirroring.
r50: RAID 50 – Spanned Striping with Parity.
r60: RAID 60 – Spanned Striping with Extra Parity.
-wp {wt | wb | fwb}: Set the write policy to Write Through, Write Back, or Forced Write Back.
74 RACADM Subcommand Details