CLI Guide

<senType> <Num> <sensorName> <status> <reading> <units> <lc>
<uc>
Temp 1 Ambient_Temp OK 21 celcius N/A 40
<
senType> <Num> <sensorName> <status> <AC-OK status>
PWR 1 PS-1 Online OK
PWR 2 PS-2 Online OK
PWR 3 PS-3 Online OK
PWR 4 PS-4 Slot Empty N/A
PWR 5 PS-5 Failed OK
PWR 6 PS-6 Slot Empty N/A
racreset
Table 80. Details of racreset
Description Performs a CMC or a RAC reset operation.
NOTE: To use this subcommand, you must have the Chassis Administrator privilege.
NOTE: When you run a racreset subcommand, iDRAC may require up to two minutes to
return to a usable state.
NOTE: You must restart your system after performing a hard reset of iDRAC.
Synopsis
racadm racreset [-m <module>]
Input (module)sled-n, where n=1–4.
NOTE: You can specify multiple modules: -m <module 1> –m <module 2>.
Example
Reset CMC:
racadm racreset
Reset server 1.
racadm racreset -m server-1
Reset servers 1 and 3.
racadm racreset -m server-1 -m server-3
racresetcfg
Table 81. Details of racresetcfg
Description Resets CMC conguration to factory default settings.
NOTE: To use this, you must have the Chassis Administrator privilege.
Synopsis
racadm racresetcfg [-m <module>] [-c <feature>]
Input
-m : <module> — Must be one of the following values:
chassis — default state, if -m is not specied.
server-n, where n=1–4
switch-n, where n=1
-c : <feature> — Must be one of the following values:
ad — Reset Active Directory properties to the default value. The default setting is “disabled”.
70 RACADM Subcommand Details