CLI Guide

NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fiber Channel, and
Inniband.
Synopsis
racadm getioinfo
racadm getioinfo [-m <module>]
racadm getioinfo [-m <module>][-s]
Input -m Species the module or device. The <module> must be switch — <n>, where n = 1–2
-s — Displays the stack information.
Table 34. Example
<IO> <Power> <Name> <Role> <Mode> <Type> <Presence> <POST>
switch-1 ON R1-PT VRTX
1Gb Master
Pass-
through
N/A Gigabit
Ethernet
Present OK
getled
Table 35. Details of getled
Description Displays the LED settings on a module: blinking, not blinking, or
unknown (for empty slots).
To use this subcommand, you must have the Login User privilege.
Synopsis
racadm getled -m <module>
Input CMC only options:
-m <module> — Species the module whose LED settings you
want to view.
<module> can be one of the following:
server-n where n=1–4
switch-n where n=1
chassis
cmc-active
Example For CMC:
racadm getled -m server-10
<module> <LED state> server-10 Blinking
racadm getled -m chassis
<module> <LED state> server-10 Not blinking
racadm getled -m server-1
<module> <LED state> server-1 ON
racadm getled -m server-9
<module> <LED state> server-9 Extension(1)
42 RACADM Subcommand Details