CLI Guide
Active CMC: The feature card inserted is
valid, serial number = CN0H871T137401112222A00
The feature card contains the following
feature(s):
FlexAddress: bound
FlexAddressPlus: bound
ExtendedStorage: bound
Standby CMC: The feature card contains the
following feature(s):
FlexAddress: not bound
FlexAddressPlus: not bound
ExtendedStorage: bound
fwupdate
Table 20. Details of fwupdate
Description
Allows you to update the rmware on the active and standby CMC rmware, chassis infrastructure rmware, and
storage component rmware (RAID controller, hard disk drive, and expander). You can:
• Check the rmware update process status.
• Update the rmware from a FTP or a TFTP server by providing an IP address and optional path.
• Update the rmware from the local le system using remote RACADM.
• The subcommand updates one or more devices of a single type at a time.
To use this subcommand, you must have the Chassis Conguration Administrator privilege.
NOTE:
• Running the subcommand to update the active CMC rmware resets the CMC, causing all network
connections to get logged o. While updating all other modules, including the standby CMC, the active
CMC continues to function normally without resetting.
• The subcommand generates an error, when used on the extension slot of a multi-slot server.
• The CMC rmware cannot be updated to any earlier version other than 2.0 for a chassis that is
congured with 1600W PSU.
• CMC rmware update or roll back is supported only for rmware versions 1.2, 1.25, 1.3, 1.31, 1.35, 1.36,
2.0, and later. For any version other than these, rst update to any of these versions, and then update
to the required version.
For 13th generation and later, CMC rmware includes a signature which is veried by CMC before update to
ensure the authenticity of the uploaded rmware. The rmware update process is successful only if the rmware
image is authenticated by CMC to be a valid image from the service provider and has not been altered. The
rmware update process is stopped if CMC cannot verify the signature of the uploaded rmware image.
Upload rmware image from TFTP server and start rmware update.
NOTE
: Run the rmware update command through only one remote racadm session at a time.
Synopsis
• Using Remote RACADM:
racadm -r fwupdate -p -u -d <firmware image>
NOTE: iDRAC7 targets are not supported from CMC. Use the CMC GUI to update iDRAC7 targets
from CMC.
When using FTP, if you provide the full path to the image le on the CLI, then the CMC uses that path to
locate that le on the host. If you do not provide a full path, then the CMC searches the home directory of
the specied user for the le if the host system is running Linux or another variant of UNIX. If the host
system is running Windows, then a default folder, such as C:\ftproot is searched.