User's Manual

426 Diagnostics
Front Panel LCD Messages
This section contains two subsections that list error and status information
that is displayed on the front panel LCD.
Error messages on the LCD have a format that is similar to the System Event
Log (SEL) viewed from the CLI or Web interface. The format is as follows:
<Severity> <Sensor Name>: <Sensor Type> sensor for
<Entity>, <Description of event>
The tables in the error section list the error and warning messages that are
displayed on the various LCD screens and the possible cause of the message.
Text enclosed in angled brackets (< >) indicates that the text may vary.
Status information on the LCD includes descriptive information about the
modules in the chassis. The tables in this section describe the information
that is displayed for each component.
LCD Error Messages
Table 13-3. CMC Status Screens
Severity Message Cause
Critical The CMC <number> battery
failed.
CMC CMOS battery is missing or
has no voltage.
Critical CMC <number> LAN heartbeat
was lost.
The CMC NIC connection has
been removed or is not connected.
Warning A firmware or software
incompatibility detected between
iDRAC in slot <number> and
CMC.
Firmware between the two devices
does not match in order to support
one or more features.
Warning A firmware or software
incompatibility detected between
system BIOS in slot <number>
and CMC.
Firmware between the two devices
does not match in order to support
one or more features.
Warning A firmware or software
incompatibility detected between
CMC 1 and CMC 2.
Firmware between the two devices
does not match in order to support
one or more features.