User's Manual
384 Troubleshooting and Recovery
4
Enable traps alerting by typing:
racadm config -g cfgTraps -o cfgTrapsEnable 1 -i
<index>
where
<index>
is a value 1–4. The index number is used by CMC to
distinguish up to four configurable destinations for traps alerts.
Destinations may be specified as appropriately formatted numeric
Addresses (IPv6 or IPv4), or Fully-qualified domain names (FQDNs).
5
Specify a destination IP address to receive the traps alert by typing:
racadm config -g cfgTraps -o
cfgTrapsAlertDestIPAddr <IP address> -i <index>
where
<IP address>
is a valid destination, and
<index>
is the index
value you specified in step 4.
6
Specify the community name by typing:
racadm config -g cfgTraps -o cfgTrapsCommunityName
<community name> -i <index>
where
<community name>
is the SNMP community to which
the chassis belongs, and
<index>
is the index value you specified in
steps 4 and 5.
IOM Failure 0x200000
Firmware Version Mismatch 0x00400000
Chassis Power Threshold Error 0x01000000
SDCARD Absent 0x02000000
SDCARD Error 0x04000000
Chassis Group Error 0x8000000
Table 12-3. Event Traps Filter Masks
(continued)
Event Filter Mask Value