User's Manual

320 Power Management
Configuring Power Budget and Redundancy
CMC’s power management service optimizes power consumption for
the entire chassis (the chassis, servers, IOMs, iKVM, CMC, and PSUs)
and re-allocates power to different modules based on the demand.
Using the Web Interface
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
1
Log in to the CMC Web interface
.
2
Select
Chassis Overview
in the system tree.
3
Click
Power
Configuration
.
The
Budget/Redundancy Configuration
page displays.
4
Set any or all of the properties described in Table 9-16 according
to your needs.
5
Click
Apply
to save your changes.
To refresh the content on the Budget/Redundancy Configuration page,
click Refresh. To print the contents, click Print.
Table 9-15. Chassis Power Supplies
Item Description
Name Displays the name of the PSU in the format PS-n, where n, is the
PSU number.
Power State Displays the power state of the PSU — Initializing, Online, Stand
By, In Diagnostics, Failed, Unknown, or Absent (missing).
Input Volts Displays the present input voltage of the power supply.
Input Current Displays the present input current of the power supply.
Output Rated
Power
Displays the maximum output power rating of the power supply.