User's Manual

302 Power Management
To disable Server Performance Over Power Redundancy, perform the
following steps:
1
Click
Chassis Overview
in the system tree.
2
Click
Power
Configuration
.
3
Clear Server
Performance Over Power Redundancy
and click
Apply
.
Using RACADM
To enable Server Performance Over Power Redundancy, perform the following
steps:
1
Open a serial/Telnet/SSH text console to CMC and log in.
2
Enable Server Performance Over Power Redundancy:
racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 1
To disable Server Performance Over Power Redundancy, perform the
following steps:
1
Open a serial/Telnet/SSH text console to CMC and log in.
2
Disable Server Performance Over Power Redundancy:
racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 0
Remote Logging
Power consumption can be reported to a remote syslog server. Total chassis
power consumption, minimum, maximum, and average power consumption
over a collection period can be logged. For more information on enabling this
feature and configuring the collection/logging interval, see related sections
below.
Using the Web Interface
You can enable power remote logging using the GUI. To do so, log in to the
GUI, and do the following:
1
Click
Chassis Overview
in the system tree.
2
Click
Power
Configuration
.