User's Manual
192 Using the CMC Web Interface
• Update status displays in the
Update State
field; this field is
automatically updated during the file transfer process.
NOTE: The update may take several minutes for CMC.
5
For a standby CMC, when the update is complete the
Update State
field
displays "Done". For an active CMC, during the final phases of the
firmware update process, the browser session and connection with CMC is
lost temporarily as the active CMC is taken offline. You must log in again
after a few minutes, when the active CMC has rebooted.
After CMC resets, the new firmware is displayed on the
Firmware Update
page.
NOTE: After the firmware update, clear the Web browser cache. See your Web
browser’s online help for instructions on how to clear the browser cache.
Updating the iKVM Firmware
NOTE: The iKVM resets and becomes temporarily unavailable after the firmware
has been uploaded successfully.
1
Log back in to CMC Web interface.
2
Select
Chassis Overview
in the system tree.
3
Click the
Update
tab. The
Firmware Update
page appears.
4
Select the iKVM to update by selecting the
Update Targets
check box for
that iKVM.
5
Click the
Apply iKVM Update
button below the iKVM component list.
6
In the
Firmware Image
field, enter the path to the firmware image file on
your management station or shared network, or click
Browse
to navigate to
the file location.
NOTE: The default iKVM firmware image name is ikvm.bin; however, the iKVM
firmware image name can be changed by the user to avoid confusion with previous
images.
7
Click
Begin Firmware Update
.
8
Click
Yes
to continue. The
Firmware Update Progress
section provides
firmware update status information. A status indicator displays on the
page while the image file uploads. File transfer time can vary greatly based
on connection speed. When the internal update process begins, the page
automatically refreshes and the Firmware update timer displays.
Additional instructions to follow: