User's Manual
182 Using the CMC Web Interface
Idle Timeout Displays the number of seconds before an idle serial session
is automatically disconnected. A change to the Timeout
setting takes effect at the next login; it does not affect the
current session.
Timeout Range: 0 or 60 to 10800 seconds. To disable the
Timeout feature, enter 0.
Default: 1800 seconds
Baud Rate Displays the data speed on the external serial port on
the CMC.
Configuration options: 9600, 19200, 28800, 38400, 57600,
and 115200 bps.
Default: 115200 bps
Authentication
Disabled
Enables CMC Serial Console login authentication.
Default: Unchecked (disabled)
Escape Key Allows you to specify the Escape key combination that
terminates serial/text console redirection when using the
connect or racadm connect command.
Default: ^\
(Hold <Ctrl> and type a backslash (\) character)
NOTE: The caret character ^ represents the <Ctrl> key.
Configuration options:
• Decimal value (example: 95)
• Hexadecimal value (example: 0x12)
• Octal value (example: 007)
• ASCII value (example: ^a)
ASCII values may be represented using the following
Escape key codes:
• Esc followed by any alphabetic character (a-z, A-Z)
• Esc followed by the following special characters: [ ] \ ^ _
• Maximum Allowed Length: 4
Table 5-50. CMC Serial Console Settings
(continued)
Setting Description