Quick Reference Guide
RACADM Subcommand Details 93
NOTE: The -b and -c options are not available for CMC modules.
Example
• racadm getversion -m server-15
<server> <iDRAC version> <model name> <Gen> <Updatable>
server-15 2.00(Build 10) PowerEdgeM605 iDRAC N
racadm getversion
• racadm getversion -c
-m
<module>
Specifies the module or device for which you want to retrieve the
version information.
<module> is one of the following:
•
server
-
n
where
n
= 1
-
16. For example,
server-1
.
•cmc-
n
where n= 1 or 2. For example,
cmc-2
.
-c Displays the server's current CPLD version.
-b Displays the server's current BIOS version (default is iDRAC version).
<Server> <iDRAC Version> <Blade Type> <Gen> <Updatable>
server-2 1.50 PowerEdgeM600 iDRAC Y
server-3 2.10 PowerEdgeM610 iDRAC6 Y
server-4 1.50 PowerEdgeM605 iDRAC Y
<CMC> <CMC Version> <Updatable>
cmc-1 2.10.X06.200906
080825
Y
<Server> <CPLD Version> <Blade Type>
server-1 PowerEdgeM600
server-2 PowerEdgeM805
server-5 1.0.0 PowerEdgeM710
Table 2-23. getversion Subcommand Options
Option Description