Quick Reference Guide

36 RACADM Subcommand Details
Options
Example
Perform a reset of switch-3.
racadm chassisaction -m switch-3 reset
Module power operation successful.
clearasrscreen
NOTE: To use this subcommand, you must have Clear Logs permission.
Table 2-1. chassisaction Subcommand Options
Option Description
-m <module> Specifies the module on which you want the action carried out.
<module> may be one of the following:
chassis
- this is the default value if
-m
is not specified.
switch-n
where
n
=1–6
kvm
<action> Specifies the action you want to execute on the specified module.
<action> may be one of the following:
powerdown
— (Chassis only) Powers down the chassis.
powerup
— (Chassis only) Powers up the chassis.
powercycle
— Power cycles the module.
nongraceshutdown
— (Chassis only) Shuts down the chassis
non-gracefully.
reset
— Performs a hard reset of the module.
NOTE: When <
module
> = kvm or switch, <
action
> must be powercycle or reset.
Subcommand Definition
clearasrscreen Clears the last crash (ASR) screen that is in memory. See
Configuring the Managed Server to Capture the Last Crash
Screen and Disabling the Windows Automatic Reboot Option
sections in the iDRAC6 Enterprise for Blade Servers User
Guide.