Quick Reference Guide
252 iDRAC6 and CMC Property Database Group and Object Definitions
FILE LOCATION: C:\Workarea\CMC_iDrac_AdminrefGuide\iDRAC Admin Reference
Guide\EN\Source\racadmDBgrpObjDef.fm
DELL CONFIDENTIAL – PRELIMINARY 12/7/10 - FOR PROOF ONLY
cfgDNSCurrentDomainName
Displays the DNS domain name.
cfgNicCurrentIPv4Enabled
Indicates whether IPv4 is enabled on the CMC. If the current property value
is set to 0 (false), the remote network interfaces to the CMC are not
accessible over IPv4.
Example
racadm getconfig -g cfgCurrentLanNetworking
# cfgNicCurrentIPv4Enabled=1
# cfgNicCurrentIpAddress=143.166.152.116
# cfgNicCurrentNetmask=255.255.255.0
# cfgNicCurrentGateway=143.166.152.1
# cfgNicCurrentDhcpWasUsed=0
# cfgNicCurrentVlanEnable=0
# cfgNicCurrentVlanID=1
# cfgNicCurrentVlanPriority=0
# cfgDNSCurrentServer1=192.168.0.5
# cfgDNSCurrentServer2=192.168.0.6
# cfgDNSCurrentDomainName=MYDOMAIN
cfgCurrentIPv6LanNetworking (read only)
NOTE: This object property is applicable only for CMC. Use this object with the
getconfig subcommand.
NOTE: To use this object property, you must have CMC Login User privilege.
Description
Displays the current CMC IPv6 properties.
cfgCurrentIPv6Enabled
Indicates whether IPv6 is enabled on the CMC. If the current property value
is set to 0 (false), the remote network interfaces to the CMC are not
accessible over IPv6.