cfgChassisInPowerServerAllocation (Read Only)
Indicates (in watts) the cumulative power allocated to servers. There is no
default as this parameter is very specific to the particular customer
configuration.
cfgChassisInfrastructureInPowerAllocation (Read Only)
Indicates the estimated cumulative DC output power consumption (in
watts), determined from a field replaceable unit (FRU) on the hardware
modules in the chassis.
cfgChassisTotalInPowerAvailable (Read Only)
Indicates the amount of power (in watts) available for use by the chassis.
cfgChassisStandbyInPowerCapacity (Read Only)
Indicates the amount of power (in watts) available for powering up any
hardware modules that are either added to the chassis or powered up (if they
are already present in the chassis).
cfgChassisPowerClear (Write Only)
To reset cfgChassisMinPower and cfgChassisMaxPowerCapacity, set this
object to 1.
cfgChassisPowerClearTimestamp (Read Only)
Time stamp when cfgChassisMinPower and cfgChassisMaxPowerCapacity
were reset.
cfgChassisPowerButtonEnable
Description Indicates if the chassis power button is enabled or disabled.
Legal Values 0 (disabled)
1 (enabled).