cfgChassisMaxPowerConservationMode
cfgChassisPerformanceOverRedundancy
cfgChassisInMaxPowerCapacity (Read Only)
Indicates the total chassis power budget (in watts) available for chassis
operation.
cfgChassisInRedundancyReserve (Read Only)
Indicates the amount of redundant power (in watts) in reserve that can be
utilized in the event of an AC grid or PSU failure. This value is 0 if the
Redundancy Policy is set to 0 (no redundancy).
Description Enables or disables max power conservation mode. When enabled,
all servers are immediately reduced to their minimum power levels,
and all subsequent server power allocation requests are denied. In
this mode performance of powered on servers may be degraded, and
additional servers cannot be powered on, regardless of server
priority.
Legal Values 0 (disabled)
1 (enabled)
Default 0 (disabled)
Description Enables or disables server performance over power redundancy.
When enabled, this option favors server performance and server
powerup, over maintaining power redundancy. When disabled, the
system favors power redundancy over server performance. When
disabled, then if the power supplies in the chassis do not provide
sufficient power, both for redundancy, as well as full performance,
then some servers may not be granted sufficient power for full
performance, or may not be powered on, in order to maintain
redundancy.
Legal Values 0 (disabled)
1 (enabled)
Default 1 (enabled)