Quick Reference Guide

iDRAC6 and CMC Property Database Group and Object Definitions 213
FILE LOCATION: C:\Workarea\CMC_iDrac_AdminrefGuide\iDRAC Admin Reference
Guide\EN\Source\racadmDBgrpObjDef.fm
DELL CONFIDENTIAL – PRELIMINARY 12/7/10 - FOR PROOF ONLY
cfgChassisRedundancyPolicy
cfgChassisDynamicPSUEngagementEnable
cfgChassisAllow110VACOperation
Description Sets the redundancy policy of the chassis.
Legal Values 0 (no redundancy)
1 (AC redundancy)
2 (power supply redundancy)
Default 0 (no redundancy)
Description Enables or disables dynamic engagement.
Legal Values 0 (disabled)
1 (enabled)
Default 0 (disabled)
Description Enables or disables normal chassis power allocations when any
power supply unit is connected to 110V AC service. If disabled and
110V power supplies are detected, all subsequent server power
allocation requests are denied. In this mode additional servers
cannot be powered on, regardless of server priority.
Legal Values 0 (disabled)
1 (enabled)
Default 0 (disabled)