Quick Reference Guide
iDRAC6 and CMC Property Database Group and Object Definitions 209
FILE LOCATION: C:\Workarea\CMC_iDrac_AdminrefGuide\iDRAC Admin Reference
Guide\EN\Source\racadmDBgrpObjDef.fm
DELL CONFIDENTIAL – PRELIMINARY 12/7/10 - FOR PROOF ONLY
cfgChassisPower
This group is applicable only to CMC and contains parameters to display or
configure power for the chassis.
NOTE: Use this object with the config or getconfig subcommands.
NOTE: To use this object property, you must have Chassis Configuration
Administrator privilege.
NOTE: You can configure any setting that is not preceded by the hash sign (#) in
the output. To modify a configurable object, use the -o option.
The following sections provides information about the objects in the
cfgChassisPower group.
cfgChassisInPower (Read Only)
Indicates the cumulative input power consumption data (in watts and
BTU/hr) captured from all healthy and functional PSUs in the chassis.
cfgChassisPeakPower (Read Only)
The maximum system input power consumption (in watts) since the value
was last cleared by a user.
cfgChassisPeakPowerTimestamp (Read Only)
The timestamp recorded when the peak input power consumption value
occurred.
cfgChassisMinPower (Read Only)
The minimum system input power consumption value (in watts) over the
time since the value was last cleared.
cfgChassisMinPowerTimestamp (Read Only)
The timestamp recorded when the minimum system power occurred.