Quick Reference Guide
iDRAC6 and CMC Property Database Group and Object Definitions 169
FILE LOCATION: C:\Workarea\CMC_iDrac_AdminrefGuide\iDRAC Admin Reference
Guide\EN\Source\racadmDBgrpObjDef.fm
DELL CONFIDENTIAL – PRELIMINARY 12/7/10 - FOR PROOF ONLY
Example
racadm getconfig -g cfgSerial
cfgSerialBaudRate=115200
cfgSerialConsoleEnable=1
cfgSerialConsoleQuitKey=^\
cfgSerialConsoleIdleTimeout=1800
cfgSerialConsoleNoAuth=0
cfgSerialConsoleCommand=
cfgSerialConsoleColumns=0
cfgSerialHistorySize=8192
cfgSerialTelnetEnable=0
cfgSerialSshEnable=1
cfgSerialTelnetEnable (Read/Write)
cfgOobSnmp
This group contains parameters to configure the SNMP agent and trap
capabilities of iDRAC6 or CMC. One instance of the group is allowed.
The CMC SNMP agent supports the standard RFC1213 mib-2, and the Dell
enterprise-specific MIB.
NOTE: For CMC, use this object with the config or getconfig subcommands.
NOTE: To use this object property for CMC, you must have Chassis Configuration
Administrator privilege.
NOTE: For CMC, you can configure any setting that is not preceded by the hash
sign (#) in the output. To modify a configurable object, use the -o option.
The following sections provides information about the objects in the
cfgOobSnmp group.
Description Enables or disables the Telnet console interface on iDRAC6 or
CMC.
Legal Values 1 (TRUE)
0 (FALSE)
Default 0