Quick Reference Guide
iDRAC6 and CMC Property Database Group and Object Definitions 165
FILE LOCATION: C:\Workarea\CMC_iDrac_AdminrefGuide\iDRAC Admin Reference
Guide\EN\Source\racadmDBgrpObjDef.fm
DELL CONFIDENTIAL – PRELIMINARY 12/7/10 - FOR PROOF ONLY
cfgSerial
This group contains configuration parameters for iDRAC6 or CMC services.
One instance of the group is allowed.
NOTE: Use this object with the config or getconfig subcommands.
NOTE: To use this object property for CMC, you must have Chassis Configuration
Administrator privilege.
The following sections provides information about the objects in the
cfgSerial group.
NOTE: The cfgSerial object group is applicable only for iDRAC6 on Rack and Tower
Servers and not for iDRAC6 Enterprise on Blade Servers.
cfgSerialBaudRate (Read/Write)
cfgSerialConsoleEnable (Read/Write)
Description Sets the baud rate on iDRAC6 or CMC serial port.
Legal Values For iDRAC6: 9600, 28800, 57600, 115200
For CMC: 2400, 4800, 9600, 19200, 28800, 38400, 57600,115200
Default For iDRAC6: 57600
For CMC: 115200
Description Enables or disables the RAC or CMC serial console interface.
Legal Values 1 (TRUE)
0 (FALSE)
Default For iDRAC6: 0
For CMC: 1