Quick Reference Guide

108 RACADM Subcommand Details
•The
-s
option enables static IP settings. The IPv4 address, netmask, and
gateway can be specified. Otherwise, the existing static settings are used.
<
IPv4Address
>
,
<
netmask
>
, and
<
gateway
>
must be typed as dot-
separated strings.
racadm setniccfg -s 192.168.0.120 255.255.255.0
192.168.0.1
•The
-s6
option enables static IPv6 settings. The IPv6 address, Prefix
Length, and the IPv6 Gateway can be specified.
•The
-o
option disables the NIC completely.
NOTE: The terms NIC and Ethernet management port may be used
interchangeably.
Synopsis
racadm setniccfg -d
racadm setniccfg -d6
racadm setniccfg -s <IPv4Address> <netmask> <IPv4
gateway>
racadm setniccfg -s6 <IPv6 Address> <IPv6 Prefix
Length> <IPv6 Gateway>
racadm setniccfg -o
Output
The setniccfg subcommand displays an appropriate error message if the
operation is not successful. If successful, a message is displayed.
setractime
NOTE: To use this subcommand, you must have Administrator privilege.
Description
Sets the date and time on the CMC.