Owner's Manual
file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc3_1/en/readme/CMC_README.TXT[10/26/2012 2:20:22 PM]
- 1.1.0 for Dell PowerEdge M605, M805, M905
######################################################################
RELEASE HIGHLIGHTS
######################################################################
* Multi-chassis management that allows up to 8 other chassis to be visible
from the lead chassis.
* Power log feature that periodically samples and displays chassis
system input power (total AC consumption).
* Server Performance over Power Redundancy, which when enabled,
favors server performance and server powerup, over maintaining power
redundancy. When disabled, the system favors power redundancy over
server performance.
* Provides option to use the chassis in Maximum Power Conservation
Mode to extend power life while running on UPS or other backup power
sources.
* Save and restore configuration on a host.
* Improvement of SEL log.
* GPL/Open Source compliant.
* Dell 8/4 Gpbs Fibre Channel Pass Thru IOM.
* Dell M8428-k IOM.
* Brocade BR1741M-k Dual Port Mezzanine Card.
################################################################
KNOWN ISSUES FOR BROWSERS
################################################################
No known issues for this release.
################################################################
KNOWN ISSUES FOR CMC Version 3.1
################################################################
* While using the command "racadm config -f" with :
- CMC 3.1 or later versions of firmware, ensure that the
Remote RACADM client version 6.3.0 or later is installed.
- CMC with an earlier version of 3.1 firmware, ensure that
the Remote RACADM client version earlier than 6.3.0 is
installed.
* The racadm testfeature command for use with Active Directory