396 Troubleshooting and Recovery
NOTE: To reset components, you must have Debug Command Administrator
privilege.
To access the
Diagnostic Console
page:
1
Log in to the CMC Web interface.
2
Click
Chassis
in the system tree.
3
Click the
Troubleshooting
tab.
4
Click the
Reset Components
subtab. The
Reset Components
page
displays. The
CMC Summary
section of the
Reset Components
page
displays the following information:
Table 12-11. CMC Summary
Attribute Description
Health OK The CMC is present and communicating with
its components.
Informational Displays information about the CMC when no
change in health status (OK, Warning, Severe)
has occurred.
Warning Warning alerts have been issued, and
corrective action must be taken. If corrective
actions are not taken, critical or severe failures
that can affect the integrity of the CMC can
occur.
Severe At least one failure alert has been issued.
Severe status represents a CMC system failure,
and corrective action must be taken
immediately.
Date/Time Displays the date and time for the CMC using the format
MM/DD/YYYY, where MM is the month, DD is the date, and YYYY
is the year.
Active CMC
Location
Displays the location of the active CMC.
Redundancy
Mode
Displays Redundant if a standby CMC is present in the chassis, and
No Redundancy if no standby CMC is present in the chassis.