User's Manual
Troubleshooting and Recovery 389
Using RACADM
1
Open a serial/Telnet/SSH text console to the CMC and log in.
2
To view chassis and CMC summaries, type:
racadm getsysinfo
3
To view the iKVM summary, type:
racadm getkvminfo
4
To view the IOM summary, type:
racadm getioinfo
Table 12-7. IOM Summary
Item Description
Location Displays the slot occupied by the IOMs. Six slots are
identified by group name (A, B, or C) and slot number
(1 or 2). Slot names: A-1, A-2, B-1, B-2, C-1, or C-2.
Present Displays whether the IOM is present (Yes or No).
Name Displays the name of the IOM.
Fabric Displays the type of fabric.
Power Status Displays the power status of the IOM: On, Off, or N/A
(Absent).
Service Tag Displays the service tag of the IOM. The service tag a unique
identifier provided by the manufacturer for support and
maintenance.