User's Manual
Troubleshooting and Recovery 377
To obtain the mask value, use a scientific calculator in hex mode and
add the second values of the individual masks (1, 2, 4, etc.)
using the <OR> key.
For example, to enable trap alerts for Battery Probe Warning (0x2),
Power Supply Failure (0x1000), and KVM failure (0x80000), key 2
<OR> 1000 <OR> 200000 and press the <=> key.
The resulting hex value is 208002, and the mask value for the RACADM
command is 0x208002.
Table 12-3. Event Traps Filter Masks
Event Filter Mask Value
Fan Probe Failure 0x1
Battery Probe Warning 0x2
Temperature Probe Warning 0x8
Temperature Probe Failure 0x10
Redundancy Degraded 0x40
Redundancy Lost 0x80
Power Supply Warning 0x800
Power Supply Failure 0x1000
Power Supply Absent 0x2000
Hardware Log Failure 0x4000
Hardware Log Warning 0x8000
Server Absent 0x10000
Server Failure 0x20000
KVM Absent 0x40000
KVM Failure 0x80000
IOM Absent 0x100000
IOM Failure 0x200000
Firmware Version Mismatch 0x00400000
Chassis Power Threshold Error 0x01000000