User's Manual
Troubleshooting and Recovery 375
You can add and configure SNMP alerts using the Web interface or
RACADM.
Using the Web Interface
NOTE: To add or configure SNMP alerts, you must have Chassis Configuration
Administrator privilege.
NOTE: For added security, Dell strongly recommends that you change the default
password of the root (User 1) account. The root account is the default
administrative account that ships with the CMC. To change the default password
for the root account, click User ID 1 to open the User Configuration page. Help for
that page is available through the Help link at the top right corner of the page.
1
Log in to the CMC Web interface.
2
Select
Chassis
in the system tree.
3
Click the
Alerts
tab. The
Chassis Events
page appears.
4
Enable alerting:
a
Select the check boxes of the events for which you want to enable
alerting. To enable all events for alerting, select the
Select All
check
box.
b
Click
Apply
to save your settings.
5
Click the
Traps Settings
subtab.The
Chassis Event Alert Destinations
page displays.
6
Type a valid address in an empty
Destination
field.
NOTE: A valid address is an address that receives the trap alerts. Use the
"quad-dot" IPv4 format, standard IPv6 address notation, or FQDN. For example:
123.123.123.123 or 2001:db8:85a3::8a2e:370:7334 or dell.com
IOM Absent An expected IOM is not present.
IOM Failure The IOM is not functioning.
Firmware Version
Mismatch
There is a firmware mismatch for the chassis or server
firmware.
Chassis Power Threshold
Error
Power consumption within the chassis reached the
System Input Power Cap.
Table 12-2. Chassis Events That Can Generate SNMP
(continued)
Event Description