User's Manual
Power Management 323
5
Click the corresponding radio buttons to select one of the following
Power
Control Operations
:
•
Power On System
— Turns on the chassis power (the equivalent
of pressing the power button when the chassis power is
OFF
).
This option is disabled if the chassis is already powered
ON
.
NOTE: This action powers on the chassis and other subsystems (iDRAC on the
servers, IOMs, and iKVM). Servers will not power on.
•
Power Off System
— Turns off the chassis power. This option is
disabled if the chassis is already powered
OFF
.
NOTE: This action powers off the chassis (chassis, servers, IOMs, iKVM, and
power supplies). The CMCs remain powered on, but in virtual standby state;
a power supply unit and fans provide cooling for the CMCs in this state.
The power supply will also provide power to the fans that will be running
at low speed.
•
Power Cycle System (cold boot)
— Powers off and then reboots the
system (cold boot). This option is disabled if the chassis is already
powered
OFF
.
NOTE: This action powers off and then reboots the entire chassis (chassis,
servers which are configured to always power on, IOMs, iKVM,
and power supplies).
•
Reset CMC
— Resets the CMC without powering off (warm reboot).
(This option is disabled if the CMC is already powered off).
NOTE: This action only resets the CMC. No other components are affected.
•
Non-Graceful Shutdown
— This action forces a non-graceful power
off of the entire chassis (chassis, servers, IOMs, iKVM, and power
supplies). This does not attempt to cleanly shutdown the operating
system of the servers prior to powering off.
6
Click
Apply
. A dialog box appears requesting confirmation.
7
Click
OK
to perform the power management action (for example,
cause the system to reset).