User's Manual

Using the CMC Web Interface 185
Configuring Power Budgeting
The CMC allows you to budget and manage power to the chassis. The power
management service optimizes power consumption and re-allocates power to
different modules based on the demand.
For instructions on configuring power through the CMC, see "Configuring
and Managing Power" on page 303.
For more information on the CMC’s power management service, see "Power
Management" on page 287.
Table 5-56. Remote Syslog Configuration
Setting Description
Enabled Enables the transmission and remote capture of the CMC
log and Hardware log entries to the specified server(s).
Valid va l u es: Checked (enabled), unchecked (disabled)
Default: unchecked (disabled)
Syslog Server 1 The first of three possible servers to host a copy of
the CMC and hardware log entries. Specified as a Host
Name, an IPv6 address, or an IPv4 address.
Syslog Server 2 The second of three possible servers to host a copy of
the CMC and hardware log entries. Specified as a Host
Name, an IPv6 address, or an IPv4 address.
Syslog Server 3 The third of three possible servers to host a copy of
the CMC and hardware log entries. Specified as a Host
Name, an IPv6 address, or an IPv4 address.
Syslog Port Number Specifies the port number on the remote server for
receiving a copy of the CMC and hardware log entries. The
same port number is used for all three servers. A valid syslog
port number is in the 10-65535 range.
Default: 514