Quick Reference Guide

96 RACADM Subcommands
Options
Example
racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of
a multi-slot server.
racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the
server in slot 1.
setniccfg
NOTE: To use this subcommand, you must have Administrator privilege.
Description
Sets the IP configuration for the specified module.
Table 2-37. setled Subcommand Options
Option Description
-m <module> Specifies the module whose LED you want to configure.
<module> can be one of the following:
server-n
where
n
=1–16
switch-n
where
n
=1–6
cmc-active
chassis
-l <ledstate> Specifies whether the LED should blink.
<ledstate> can be one of the following:
0
— no blinking
1
— blinking