Quick Reference Guide
24 RACADM Subcommands
Options
Output
The SEL was cleared successfully.
Example
• Clear the CMC SEL log
racadm clrsel
• Clear the SEL log on server 1
racadm clrsel -m server-1
cmcchangeover
NOTE: To use this subcommand, you must have Administrator privilege.
Description
Changes the state of the CMC from active to standby, or vice versa, in a
redundant CMC configuration. This subcommand is useful for remote
debugging or testing purposes.
NOTE: This command is valid only in redundant CMC environments. For more
information, see the "Understanding the Redundant CMC Environment" section of
the
Dell Chassis Management Controller User Guide
.
Usage
racadm cmcchangeover
Output
CMC failover initiated successfully.
Table 2-3. clrsel Subcommand Options
Option
Description
-m <module>The value of <module> can be server-n where
n can be from 1–16.