Quick Reference Guide
CMC Property Database Group and Object Definitions 169
cfgServerDNSRegisterIMC
Enables or disables DNS name registration for the Integrated Management
Controller (iDRAC).
•
Configuration options:
0 (disable), 1 (enable)
cfgServerDNSIMCName
Displays the DNS domain name for the integrated Remote Access Controller,
iDRAC.
# cfgServerRootPassword
Write only. Displays the password for iDRAC as a series of asterisks (*). It
cannot be seen or displayed after this property is written.
# cfgServerFirstBootDevice
Write only. Sets the boot device that the server must first boot from.
# cfgServerBootOnce
Write only. Sets if the server must boot from the device once.
# cfgServerPowerConsumption
Read only. Displays the current power consumption for a server.
Example
racadm getconfig -g cfgServerInfo -i 8
# cfgServerInfoIndex=8
# cfgServerSlotNumber=8
# cfgServerServiceTag=
cfgServerName=SLOT-08
# cfgServerFW=3.0
# cfgServerBIOS=
# cfgServerBmcMacAddress=00:21:9B:FE:5F:58
# cfgServerNic1MacAddress=00:0D:56:B8:69:63