Quick Reference Guide
164 CMC Property Database Group and Object Definitions
cfgChassisDynamicPSUEngagementEnable
Enables or disables dynamic engagement.
•
Configuration options:
0 (disabled), 1 (enabled)
•
Default:
0 (disabled)
# cfgChassisAllow110VACOperation
Enables or disables normal chassis power allocations when any power supply
unit is connected to 110V AC service. If disabled and 110V power supplies are
detected, all subsequent server power allocation requests are denied. In this
mode additional servers cannot be powered on, regardless of server priority.
•
Configuration options
: 0 (disabled), 1 (enabled)
•
Default
: 0 (disabled)
# cfgChassisMaxPowerConservationMode
Enables or disables max power conservation mode. When enabled, all servers
are immediately reduced to their minimum power levels, and all subsequent
server power allocation requests are denied. In this mode performance of
powered on servers may be degraded, and additional servers cannot be
powered on, regardless of server priority.
•
Configuration options
: 0 (disabled), 1 (enabled)
•
Default
: 0 (disabled)
# cfgChassisInMaxPowerCapacity
Read only. Indicates the total chassis power budget (in watts) available for
chassis operation.
# cfgChassisInRedundancyReserve
Read only. Indicates the amount of redundant power (in watts) in reserve
that can be utilized in the event of an AC grid or PSU failure. This value is 0
if the Redundancy Policy is set to 0 (no redundancy).