Quick Reference Guide
CMC Property Database Group and Object Definitions 163
cfgChassisPowerCapFBTU
Indicates the maximum power consumption limit (in BTU/hr) for the entire
chassis. Use cfgChassisCapFBTU when power consumption is to be changed
regardless of whether server throttling is required. The command generates
an error if the value for this setting is lower than the minimum power
required for the chassis configuration.
•
Configuration range:
9264
-
39707 BTU/hr
•
Default:
39707 BTU/hr
cfgChassisPowerCapPercent
Indicates the power consumption limit as a percentage. The percentage is
computed mathematically as the minimum power + (percent * (maximum
power - minimum power)). The command generates an error if server
throttling is necessary to achieve the power goal based on the value for this
setting.
•
Configuration range:
23
-
100
•
Default:
100
cfgChassisPowerCapFPercent
Indicates the power consumption limit as a percentage. The percentage is
computed mathematically as the minimum power + (percent * (maximum
power - minimum power)). Use cfgChassisPowerCapFPercent when power
consumption is to be changed regardless of whether server throttling is
required.
•
Configuration range:
23-100
•
Default:
100
cfgChassisRedundancyPolicy
Sets the redundancy policy of the chassis.
•
Configuration options:
0 (no redundancy), 1 (AC redundancy), 2 (power
supply redundancy).
•
Default:
0 (no redundancy)