Quick Reference Guide

130 CMC Property Database Group and Object Definitions
# cfgCurrentLinkLocalAddress=
fe80::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Address1=
2009:123::e48f:9dd8:6f51:a669/64
# cfgCurrentIPv6Address2=
fd88:1::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Address3=
fd88:2::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Gateway=fe80::21c:23ff:fe77:6215
# cfgCurrentIPv6DNSServersFromDHCP6=1
# cfgCurrentIPv6DNSServer1=2009:123::1
# cfgCurrentIPv6DNSServer2=::
cfgRemoteHosts
NOTE: Use this object with the config or getconfig subcommands.
NOTE: To use this object property, you must have Chassis Configuration
Administrator privilege.
Description
Enables/disables and configures firmware updates, NTP, remote syslogging,
and SMTP email alerting. Use the -m option to apply this setting to the
iDRAC.
cfgRhostsFwUpdateTftpEnable
Enables or disables CMC firmware updates from a network TFTP server.
Configuration options:
1 (true), 0 (false)
Default:
1
cfgRhostsFwUpdateIpAddr
Specifies the IP address of the network TFTP server that has the CMC
firmware image.
Configuration options: A string representing a valid TFTP server IP address.
For example, 192.168.0.55.
Default: 0.0.0.0