Users Guide
When transferring les to and from CMC, the le transfer icon spins during the transfer. If your icon is not animated, make sure that
your browser is congured to allow animations. For more information about allowing animations in the browser, see Allow Animations
in Internet Explorer.
Signed CMC Firmware Image
For VRTX CMC 2.0 and later, the rmware includes a signature. The CMC rmware veries the signature to ensure the authenticity
of the uploaded rmware. The rmware update process is successful only if the rmware image is authenticated by CMC to be a
valid image from the service provider and has not been altered. The rmware update process is stopped if CMC cannot verify the
signature of the uploaded rmware image. A warning event is then logged and an appropriate error message is displayed.
Signature verication can be performed on VRTX rmware versions 1.2 and later. For rmware downgrade to VRTX versions earlier
than 1.2, rst update the rmware to a VRTX CMC version that is later than or equal to 1.2, but earlier than 2.0. After this update,
rmware downgrade to earlier, unsigned VRTX versions can be performed.
Updating CMC and Mainboard Firmware
The shared capabilities of External Shared PERC 8 card are not available until both CMC and mainboard rmware are updated.
NOTE:
• To view the MD12x0 cabling diagram, refer to Upgrading PowerEdge VRTX to Support Shared Storage Expansion User's
Guide or Dell Shared PowerEdge RAID Controller (PERC) 8 Cards For Dell PowerEdge VRTX Systems User’s Guide
available at dell.com/support/manuals.
• The external shared storage adapter requires that you update the CMC v2.20 or later and mainboard v2.21 or later to
support External Shared PERC 8 card.
• You cannot downgrade the CMC rmware prior to 2.2 with external shared adapters.
To update the CMC and mainboard rmware:
1. Update CMC rmware.
2. Update mainboard rmware.
3. Power down the chassis and install shared storage adapters in PCIe slot 5 and slot 6.
4. Power on chassis.
5. After powering on the chassis, update external shared storage adapters.
NOTE: By default, the external shared External Shared PERC 8 card is in non-fault tolerant mode. It has to be changed to
Fault Tolerant mode after it is cabled appropriately. For more information, refer
Upgrading PowerEdge VRTX to Support
Shared Storage Expansion
.
In an event, if you want to rollback CMC or MPC/mainboard rmware or CMC and MPC rmware version, do the following tasks:
To Rollback the CMC and mainboard rmware:
1. Power o the chassis.
2. Remove all external storage adapters from the PCI slots.
3. Power on the chassis.
4. Roll back the CMC and/or mainboard rmware.
You cannot downgrade the CMC, if external shared storage adapter is detected.
If the processes are not followed in order, system behavior becomes random and parts of the system may become unstable. The
CMC logs IOV or RAID controller messages. Only shared storage VA mappings for PERC 1 and PERC 2 are visible in the older version
of CMC. All external shared storage VA mappings do not exist in the previous version of the CMC. If an External Shared PERC 8 card
is inserted after the rollback, the CMC treats it as a non-shared adapter. It may happen that the HOST PERC driver does not
support the External Shared PERC 8 card.
48