CLI Guide
setled
Description Sets the state (blinking or not blinking) of the LED on the specied module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator privilege on
CMC. To enable the servers to blink or unblink, you must have the Server Administrator or Debug
Administrator privilege on CMC.
Synopsis
racadm setled -m <module> -l <ledState>
Input
• -m <module> - Species the module whose LED you want to congure.
<module> can be one of the following:
— server-n, where n=1–4
— switch-n, where n=1
— cmc-active
— chassis
• -l <ledstate> - Species whether the LED should blink.
<ledstate> can be one of the following:
– 0 — no blinking
– 1 — blinking
Example
• racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of a multi-slot
server.
• racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
set enclosure
Description
Sets the asset tag and asset name of the enclosures.
NOTE: Set enclosure is used for the storage expansion feature when available with shared external
PERCs.
NOTE: You cannot modify the asset names for internal enclosures.
Synopsis
racadm raid set enclosures: Enclosure.External.0-0:RAID.ChassisSlot.5-1 –p
AssetTag <value>
racadm raid set enclosures: Enclosure.External.0-0:RAID.ChassisSlot.5-1 –p
AssetName <value>
Input
-p — Species the property of the enclosure to be modied.
94 RACADM Subcommand Details