CLI Guide
getversion
Table 18. getversion
Description
Displays the current rmware version of various modules in the chassis, iDRAC version on the attached servers, and
whether the target device can be updated.
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
• racadm getversion
• racadm getversion [-b | -c] [-m <module>]
• racadm getversion -l [-m <module>] [-f <filter>]
Input
NOTE: The -b, -c and -l options are not available for CMC modules.
NOTE: The -l option requires that the Lifecycle Controller service is enabled on the servers. For version
information, see the RACADM Readme available at dell.com/support/manuals.
• (none) — Displays the version information for all targets or devices.
<Server> <iDRAC Version> <Blade Type> <Gen> <Updatable>
server-3 2.20.20.20 (41) PowerEdge M630
(VRTX) iDRAC8 Y
<Switch> <Model Name> <HW Version> <FW
Version
>
switch-1 R1-PT VRTX 1Gb Pass-through
A00 1.0.0.8
<CMC> <CMC Version> <Updatable>
cmc-1 3.00.000.201609223282 Y
cmc-2
3.00.000.201609223282 Y
<Chassis Infrastructure> <FW Version> <FQDD>
Main Board 2.21.A00.201510302495 System.Chassis.
1#Infrastructure.1
<Storage Controller> <FW Version> <FQDD>
Shared PERC8 23.13.06.0011
RAID.ChassisIntegrated.1-1
<Storage Enclosure> <FW Version> <FQDD>
VRTX2.5x25 0:0 1.02
Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
<Physical Disk> <FW Version> <FQDD>
Physical Disk 0:0:0 AS09 Disk.Bay.
0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:1 AS09 Disk.Bay.
1:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:10 AS09 Disk.Bay.
10:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:11 AS09 Disk.Bay.
11:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:12 AS09 Disk.Bay.
12:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:13 AS09 Disk.Bay.
13:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:14 AS09 Disk.Bay.
14:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:18 AS09 Disk.Bay.
18:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:19 AS09 Disk.Bay.
19:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
60
RACADM Subcommand Details