CLI Guide

To use this subcommand, you must have CMC Login User privilege.
NOTE: The service tag eld is blank for modules that do not have service tags.
Synopsis
racadm getmodinfo [-m <module>] [-A]
Input
-m <module> — Species the module for which the conguration and status information is required. The default
command (no options) displays information about all the major components in the chassis.
<module> can be one of the following values:
server-n, where n = 1 to 4
switch-n, where n = 1
CMC-n, where n = 1 or 2
fan-n, where n = 1 to 6
blower-n, where n = 1 to 4
ps-n, where n = 1 to 4
chassis
dvd
main-board
io-cable
fpc-cable
storage
-A — Does not display the headers and labels in the output.
Example
racadm getmodinfo -m switch-1
<module> <presence> <pwrState> <health> <svcTag>
<nodeId>
Switch-1 Present
ON OK N/
A N/A
racadm getmodinfo
NOTE: A power state of "Primary" denotes Active CMC.
<
module> <presence> <pwrState> <health> <svcTag>
<nodeId>
Chassis Present ON
Not OK 3BPV622 N/A
Main-Board Present ON
OK N/A N/A
Storage Present ON
OK 3BPV622
Fan-1 Unknown N/A
Not OK N/A N/A
Fan-2 Present ON
OK N/A N/A
Fan-3 Present ON
OK N/A N/A
Fan-4 Present ON
OK N/A N/A
Fan-5 Present ON
OK N/A N/A
Fan-6 Present ON
OK N/A N/A
Blower-1 Present ON
OK N/A N/A
Blower-2 Present ON
OK N/A N/A
Blower-3 Present ON
OK N/A N/A
Blower-4 Present ON
OK N/A N/A
RACADM Subcommand Details
47