CLI Guide
Gigabit
Ethernet
Present 84:8F:
69:FC:E8:F1
Unknown Factory
Switch-1 10 GbE KR Present
F8:B1:56:45:DD:
BD
N/A Factory
Displays the chassis-assigned WWN/MAC address.
racadm getmacaddress -c flexaddress
<
Name> <Type> <Presence> <Active WWN/
MAC>
<Partition
Status>
<Assignment
Type>
Server-4-A IDRAC-
Controller
Present F8:DB:88:3D:
9F:A7
N/A FlexAddress
10 GbE KR Present F8:DB:88:3D:
9F:A9
Disabled FlexAddress
10 GbE KR/3 Present F8:DB:
88:3D:A2:78
Unknown FlexAddress
10 GbE KR/3 Present F8:DB:
88:3D:A2:7B
Unknown FlexAddress
NOTE: 10 GbE KR/3— The value 3 indicates the protocol type.
Displays the console assigned MAC/WWN of all LOMs or mezzanine cards.
racadm getmacaddress -c all
<Name> <Type> <Presence> <Active WWN/MAC> <Partition
Status>
<Assignment
Type>
CMC N/A Present 34:17:EB:E6:E0:24 N/A Factory
Server-1-A 10 GbE KR Not Installed 10:98:36:AC:70:EB Not Installed Not Installed
Server-2 Not Installed Not Present Not Installed Not Installed Not Installed
Server-3-A Reserved Present
Switch-4 Not Installed Not Present Not Installed Not Installed Not Installed
Switch-1 Not Installed Not Present Not Installed N/A N/A
NOTE: If the I/O Modules in slots 1 and 2 are absent and the getmacaddress -a and getmacaddress —c all commands
are run, the output is displayed as Not Installed in the following columns:
• <Presence>
• <NIC1 MAC Address>
• <NIC2 MAC Address>
getmodinfo
Table 16. getmodinfo
Description
Displays conguration and status information for all modules or a specied module (server, switch, CMC, fan unit,
blower, power supply unit, chassis, DVD, main-board, IO cable, and FPC cable) in the chassis.
46 RACADM Subcommand Details