CLI Guide
4 Enabled Not Present
Displays the current FlexAddress setting for slot 4
racadm getflexaddr -i 4
Slot-4 server presence = Present
Slot-4 flexaddress enabled = 1
<
Name> <Type> <Server-Assigned> <Chassis-Assigned>
slot4-idrac Controller 18:A9:9B:FD:C7:57 F8:DB:88:3D:
9F:A7(active)
slot4-A 10 GbE KR 00:90:FA:51:36:54 F8:DB:88:3D:
9F:A8(active)
10 GbE KR/3 00:90:FA:51:36:55 F8:DB:88:3D:
9F:AA(active)
FCoE-WWN 10:00:00:90:FA:51:36:55 20:01:F8:DB:88:3D:
9F:AA(active)
10 GbE KR/3 00:90:FA:51:36:56 F8:DB:
88:3D:A2:78(active)
NOTE: 10 GbE KR/3— The value 3 indicates the protocol type.
getioinfo
Table 15. getioinfo
Description Displays general information about the I/O modules on the chassis.
To use this subcommand, you must have the CMC Login User privilege.
NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fiber Channel, and
Inniband.
Synopsis
racadm getioinfo
racadm getioinfo [-m <module>]
racadm getioinfo [-m <module>][-s]
Input -m — Species the module or device. The <module> must be switch — <n>, where n = 1–2
-s — Displays the stack information.
Example
racadm getioinfo
<IO> <Power> <Name> <Role> <Mode> <Type> <Presence> <POST>
switch-1 ON R1-PT VRTX
1Gb Master
Pass-
through
N/A Gigabit
Ethernet
Present OK
RACADM Subcommand Details 41