CLI Guide

cfgAlertingEnable
Description Enables or disables event traps on the CMC.
Legal Values
1 (true)
0 (false)
Default None
To use this object property, you must have the Chassis Conguration Administrator privilege.
cfgAlertingSourceEmailName
Description Species the e-mail address used to send e-mail notications when an event occurs.
Legal Values Valid e-mail address
Default None
Examples
racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName
racadm config -g cfgAlerting -o cfgAlertingSourceEmailName user@home.com
Object value modified successfully.
To use this object property, you must have Chassis Conguration Administrator and Test Alert User privileges.
cfgIPv6LanNetworking
This group is used to congure the IPv6 over LAN networking capabilities.
Use this object with the cong or getcong subcommands.
To use this object property for CMC, you must have the Chassis Conguration Administrator privilege.
The following sections provide information about the objects in the cfgIPv6LanNetworking group.
cfgIPv6Enable (Read/Write)
Description
Enables or disables the IPv6 stack.
Legal Values
1 (TRUE)
0 (FALSE)
162 CMC Property Database Group and Object Descriptions