CLI Guide
cfgChassisDynamicPSUEngagementEnable (Read/Write)
Description Enables or disables dynamic engagement.
Legal Values
• 0 (disabled)
• 1 (enabled)
Default 0 (disabled)
cfgChassisInMaxPowerCapacity (Read Only)
Description Indicates the total chassis power budget (in watts) available for chassis operation.
Legal Values None
Default None
cfgChassisInRedundancyReserve (Read Only)
Description
Indicates the amount of redundant power (in Watt) in reserve that can be utilized in the event of an
AC grid or PSU failure. This value is 0 if the Redundancy Policy is set to 0 (no redundancy).
Legal Values 0 (disabled)
1 (enabled)
Default None
cfgChassisInPowerServerAllocation (Read Only)
Description
Indicates (in Watt) the cumulative power allocated to servers. There is no default as this parameter
is very specic to the particular customer conguration.
Legal Values None
Default None
cfgChassisInfrastructureInPowerAllocation (Read Only)
Description
Indicates the estimated cumulative DC output power consumption (in watts), determined from a eld
replaceable unit (FRU) on the hardware modules in the chassis.
Legal Values None
CMC Property Database Group and Object Descriptions 157