CLI Guide
NOTE: The rmware racadm prompts you to conrm whether the FIPS mode has to be enabled, but remote racadm does not
prompt you to do so.
cfgRacTuneTLSProtocolVersionEnable
Description
Sets the minimum TLS protocol version.
Legal Values
• 0 - TLSv1.0, TLSv1.1, and TLSv1.2 are enabled.
• 1 - TLSv1.1 and TLSv1.2 are enabled.
• 2 - only TLSv1.2 is enabled.
Default 1
cfgServerInfo
For iDRAC this group allows you to select the BIOS rst boot device and provides the option to boot the selected device only once.
For CMC, this group allows you to displays information for and congure a server in the chassis.
Use this object with the cong or getcong subcommands.
To use this object property for CMC, you must have Chassis Conguration Administrator privilege.
NOTE
: For CMC, you can congure any setting that is not preceded by the hash sign (#) in the output. To modify a congurable
object, use the -o option
The following sections provide information about the objects in the cfgServerInfo group.
cfgServerInfoIndex (Read Only)
Description
Displays the index name of the server.
Legal Values None
Default None
cfgServerSlotNumber (Read Only)
Description
Species the location of the specied server (1–4) in the chassis.
Legal Values None
Default None
CMC Property Database Group and Object Descriptions 133