Users Guide

Table Of Contents
NOTE: Physical disk per enclosures, virtual disks per enclosures, and external storage component LED can be
selected on this page.
To enable blinking of a component LED, select the Select/Deselect All option corresponding to the physical disk drive or
virtual disk or enclosures, and then click Blink. To disable blinking of a component LED, clear the Select/Deselect All option
corresponding to the LED, and then click Unblink.
Configuring LED Blinking Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm setled -m <module> [-l <ledState>], where <module> specifies the module whose LED you want to
configure. Configuration options:
server-n where n = 1-4
switch-1
cmc-active
and <ledState> specifies whether or not the LED should blink. Configuration options:
0 not blinking (default)
1 blinking
racadm raid <operation> <component FQDD>, where the operation value is blink or unblink, and the FQDD is for
the component's physical disk drive, virtual disk and enclosures.
Configuring CMC Properties
You can configure CMC properties such as power budgeting, network settings, users, and SNMP and email alerts using the web
interface or RACADM commands.
Configuring iDRAC Launch Method Using CMC Web
Interface
To configure the iDRAC launch method from the General Chassis Settings page:
1. In the left pane, click Chassis Overview > Setup.
The General Chassis Settings page is displayed.
2. In the drop-down menu for the iDRAC Launch Method property, select IP Address or DNS.
3. Click Apply.
NOTE:
A DNS-based launch is used for any particular iDRAC only if:
The chassis setting is DNS.
CMC has detected that the specific iDRAC is configured with a DNS name.
Configuring iDRAC Launch Method Using RACADM
To update CMC firmware using RACADM, use the cfgRacTuneIdracDNSLaunchEnable subcommand. For more
information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available
at dell.com/support/manuals.
Configuring Login Lockout Policy Attributes Using
CMC Web Interface
NOTE: To perform the following tasks, you must have Chassis Configuration Administrator privilege.
Installing and Setting Up CMC 35