Users Guide

Table Of Contents
To display the Ethernet and iSCSI MAC/WWN addresses for all iDRAC/LOMs/mezzanine cards, use the following RACADM
command:
racadm getmacaddress -a
For more information on the getflexaddr and getmacaddress subcommand, see the Chassis Management Controller for
PowerEdge VRTX RACADM Command Line Reference Guide.
Command Messages
The following table lists the RACADM commands and output for common FlexAddress situations.
Table 35. FlexAddress Commands and Output
Situation Command Output
SD card in the active CMC module is
bound to another service tag.
$racadm featurecard -s
The feature card inserted
is valid and contains the
following feature(s)
FlexAddress: bound to another
chassis, svctag = <Service tag
Number> SD card SN = <Valid
flex address serial number>
SD card in the active CMC module
that is bound to the same service tag.
$racadm featurecard -s
The feature card inserted
is valid and contains the
following feature(s)
FlexAddress: bound
SD card in the active CMC module
that is not bound to any service tag.
$racadm featurecard -s
The feature card inserted
is valid and contains the
following feature(s)
FlexAddress:not bound
FlexAddress feature not active on
the chassis for any reason (No SD
card inserted/ corrupt SD card/ after
feature deactivated /SD card bound
to a different chassis).
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i
<slot#> <slotstate>]
ERROR: Flexaddress feature is
not active on the chassis
Guest user attempts to set
FlexAddress on slots/fabrics.
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i
<slot#> <slotstate>]
ERROR: Insufficient user
privileges to perform
operation
Deactivating FlexAddress feature with
chassis powered ON.
$racadm feature -d -c
flexaddress
ERROR: Unable to deactivate
the feature because the
chassis is powered ON
Guest user tries to deactivate the
feature on the chassis.
$racadm feature -d -c
flexaddress
ERROR: Insufficient user
privileges to perform
operation
Changing the slot/fabric FlexAddress
settings while the server modules are
powered ON.
$racadm setflexaddr -i 1 1
ERROR: Unable to perform
the set operation because it
affects a powered ON server
156 Using FlexAddress and FlexAdress Plus