Users Guide

Figure 5. Eight quarter-width sleds in the chassis
Four FM120x4 sleds in the chassis:
NOTE: The Reserved QuickDeploy IPAddresses must be set to 16.
Figure 6. Four FM120x4 sleds in the chassis
Top row contains only quarter-width sleds and bottom row contains only half-width sleds:
NOTE: The Reserved QuickDeploy IPAddresses must be set to a minimum of 8.
Figure 7. Quarter-width sleds in top row and half-width sleds in bottom row
Top row contains only full-width sleds and bottom row contains only half-width sleds:
Figure 8. Full-width sleds in top row and half-width sleds in bottom row
Top row contains full-width sleds and bottom row contains only quarter-width sleds:
NOTE: The Reserved QuickDeploy IPAddresses must be set to a minimum of 8.
Figure 9. Full-width sleds in top row and quarter-width sleds in bottom row
Modifying iDRAC Network Settings for individual server
iDRAC
Using this feature, you can configure the iDRAC network configurations settings for each installed server. The initial values displayed for
each of the fields are the current values read from the iDRAC. To use this feature, you must have an Enterprise License.
To modify the iDRAC Network Settings:
1. In the left pane, click Server Overview, and then click Setup. On the Deploy iDRAC page the iDRAC Network Settings section
lists the iDRAC DNS name, IPv4 and IPv6 network configuration settings of all the installed servers.
2. Modify the iDRAC network settings as required for the servers.
NOTE:
You must select the Enable LAN option to specify the IPv4 or IPv6 settings. For information about the fields,
see the
CMC for Dell PowerEdge FX2/FX2s Online Help
.
3. To deploy the setting to iDRAC, click Apply iDRAC Network Settings. Any changes made to the QuickDeploy Settings are also
saved.
The iDRAC Network Settings table reflects future network configuration settings; the values shown for installed servers may or may
not be the same as the currently installed iDRAC network configuration settings. Click Refresh to update the iDRAC Deploy page
with each installed iDRAC network configuration settings after changes are made.
NOTE:
Changes made to QuickDeploy fields are immediate, but changes that are made to one or more iDRAC server
network configuration settings may require a couple of minutes to propagate from CMC to iDRAC. Clicking Refresh
too soon may display only partially correct data for a one or more iDRAC servers.
Configuring servers 79