Release Notes

Known Issues
Topics:
Different PCIe card device name displayed on the iDRAC and CMC GUIs
Error occurs while importing CMC configuration file
Value of power available for server power on increases after PSU failure
Unable to view chassis logs from remote RACADM
Static IPv6 IP address can be assigned to iDRAC blades
Different PCIe card device name displayed on the
iDRAC and CMC GUIs
Description PCIe card device name displayed on the iDRAC GUI and CMC GUI is not same for Broadcom/Qlogic 10G card.
Resolution Refer to the iDRAC GUI, it is accurate and current.
Versions/Systems
affected
None
Error occurs while importing CMC configuration
file
Description
An error occurs while importing CMC configuration file using local or remote RACADM.
Resolution This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using the
command, racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0.
Versions/Systems
affected
CMC for PowerEdge FX2 1.10 or later
Value of power available for server power on
increases after PSU failure
Description
The value of "Power Available for Server Power-on” can increase after PSU failure and recovery, without any
changes to the underlying chassis hardware components.
Resolution For actual power consumption of the chassis, in the CMC GUI, go to the Chassis Overview > Power > Power
Monitoring > System Input Power .
Versions/Systems
affected
All versions of FX2/FXs
Unable to view chassis logs from remote RACADM
Description
Unable to view chassis logs from remote RACADM
Resolution None
Use firmware RACADM instead, to view the chassis logs.