CLI Guide

Table 87. Details of serveraction (continued)
Example Turn off server 3 from the CMC.
racadm serveraction -m server-3 powerdown
Server power operation successful.
Turn off server 3 from iDRAC.
racadm serveraction powerdown
Server power operation successful
Turn off server 3 from CMC when power is already turned off on that server.
racadm serveraction -m server-3 powerdown
Server is already powered OFF.
Turn off the server from CMC when power is already turned off on that server.
racadm serveraction powerdown
Server is already powered OFF
Get Power Status of server 2 on CMC
racadm serveraction -m server-2 powerstatus
ON
Get Power status action on multinode server:
racadm serveraction -m server-1a powerstatus
Get Power Status on iDRAC
racadm serveraction powerstatus
Server Power Status: ON
Reseat action on a multinode sled
racadm serveraction -f -m sled-1 reseat
Explanation of Support
CMC needs to support graceful shutdown
The support of address individual blades is expected on the CMC
set
Table 88. Details of set
Description
Import saved CMC or server configuration, or CMC Event Filter configuration from a file.
NOTE: If CMC is not in the network, you cannot import the chassis configuration profile
from a remote network share with proxy using the set command. But, you can import the
chassis configuration profile from the local management station.
82 RACADM Subcommand Details