CLI Guide
Table 75. Details of getversion (continued)
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
• racadm getversion
• racadm getversion [-b | -c] [-m <module>]
• racadm getversion -l [-m <module>] [-f <filter>]
Input
NOTE: The -b, -c and -l options are not available for CMC modules.
NOTE: The -l option requires that the Lifecycle Controller service is enabled on the
servers. For version information, see the RACADM Readme available at dell.com/
support/manuals.
• (none) — Displays the version information for all targets or devices.
<Server> <iDRAC Version> <Blade Type>
<Gen> <Updatable>
server-1a 2.15.15.15 (18) PowerEdge FC430
iDRAC8 Y
server-1b 2.40.40.40 (13) PowerEdge FC430
iDRAC8 Y
server-1c 2.10.10.10 (49) PowerEdge FC430
iDRAC8 Y
server-1d 2.40.40.40 (13) PowerEdge FC430
iDRAC8 Y
server-3a 2.10.10.10 (27) PowerEdge FC430
iDRAC8 Y
server-3b 2.10.10.10 (49) PowerEdge FC430
iDRAC8 Y
server-3c 2.30.30.30 (10) PowerEdge FC430
iDRAC8 Y
server-3d 2.10.10.10 (49) PowerEdge FC430
iDRAC8 Y
<Switch> <Model Name> <HW
Version> <FW Version>
switch-1 1GBE PASS-THROUGH MODULE A00
N/A
<CMC> <CMC
Version> <Updatable>
cmc
2.00.000.20161003sahu Y
<Chassis Infrastructure> <FW Version> <FQDD>
Main Board 1.20.A00.201502058
System.Chassis.1#Infra
structure.1
• -b — Displays the server's current BIOS version (default is iDRAC version).
• -c — Displays the server's current CPLD version.
• -l — Displays the firmware versions Lifecycle Controller components.
• -f < filter > — Filters the components. Must be used with -1 and be one of the following values:
○ bios: BIOS
○ idrac: iDRAC
○ usc: Unified Server Configurator (Lifecycle Controller)
○ diag: 32-bit Diagnostics
○ drivers: OS Driver Package
○ nic-x: Network Interface card. See -l output for possible values of x.
• -m < module > — Specifies the module or device for which you must retrieve the version
information.
66
RACADM Subcommand Details